Back to Incidents
resolved major ID: INC-2025-003

Optical Transceiver Failure Impacting Netherlands Traffic Flow

Reported: July 8, 2025 at 07:00 UTC Last Updated: December 9, 2025 at 09:18 UTC

Incident Details

Summary Optical transceiver failure causing traffic flow disruption to Netherlands with intermittent packet loss and port instability
Duration 7h 20m
Affected Services Netherlands Transit, International Peering, Customer Traffic
Impact Optical Transceiver, Netherlands, Packet Loss, Port Flapping, Hardware

Summary

On July 8, 2025, AS214503 experienced a critical optical transceiver failure affecting traffic flow to the Netherlands. The faulty transceiver caused intermittent port flapping and elevated packet loss, requiring immediate stabilization measures. The incident began at 07:00 UTC and was fully resolved at 14:20 UTC, lasting 7 hours and 20 minutes.

The affected port was administratively shut down at 09:00 UTC to prevent network instability while awaiting hardware replacement. The replacement transceiver arrived at 13:00 UTC, was installed, and full service was restored by 14:00 UTC with all traffic flows operating normally.

Impact

  • Primary Cause: Hardware failure of optical transceiver module
  • Affected Region: Netherlands traffic flows
  • Symptoms:
    • Intermittent port flapping causing link instability
    • Elevated packet loss during flapping events
    • Degraded traffic flow to Netherlands destinations
  • Mitigation: Port administratively shut down at 09:00 UTC to stabilize network
  • Customer Impact:
    • Reduced capacity to Netherlands
    • Traffic rerouting through alternate paths
    • Intermittent connectivity issues for Netherlands-destined traffic
  • Geographic Scope: Netherlands and transit services routing through affected infrastructure

Timeline (All times UTC)

07:00 - Initial error triggers detected on optical transceiver, automated monitoring alerts NOC
07:15 - NOC confirms hardware-level transceiver malfunction, elevated error rates observed
07:30 - Port flapping events begin, causing intermittent link instability
08:00 - Packet loss measurements show intermittent spikes correlating with flapping events
08:30 - Traffic engineering implemented to minimize impact while maintaining port online
09:00 - Port administratively shut down to stabilize network and prevent further flapping
09:10 - Network stability confirmed, traffic successfully rerouted through alternate paths
09:15 - Hardware replacement part ordered with expedited shipping
13:00 - Hardware replacement part arrives
13:15 - Physical transceiver replacement procedure initiated
13:30 - Port configuration restoration and initial testing completed
13:45 - Gradual traffic restoration commenced, initial monitoring positive
14:00 - Full service recovery achieved, traffic flow to Netherlands restored
14:20 - Incident resolved, all systems operating normally, monitoring confirmed stable

Root Cause

Primary Cause: Hardware failure of optical transceiver module causing intermittent signal degradation. The transceiver exhibited unstable behavior leading to port flapping and packet loss events.

Contributing Factors:

  • Normal hardware lifecycle limitations
  • Environmental factors (temperature, humidity) under investigation
  • No indication of external damage or configuration issues

Resolution

Immediate Actions:

  • Monitored transceiver health metrics and implemented traffic engineering (07:00-09:00 UTC)
  • Administratively shut down affected port at 09:00 UTC to prevent network instability
  • Verified traffic rerouting and network stability at 09:10 UTC
  • Expedited hardware replacement procurement at 09:15 UTC

Recovery Actions:

  • Received hardware replacement at 13:00 UTC
  • Completed physical transceiver replacement at 13:15 UTC
  • Restored port configuration and completed initial testing at 13:30 UTC
  • Implemented gradual traffic restoration with monitoring at 13:45 UTC
  • Achieved full service recovery at 14:00 UTC
  • Confirmed stable operation at 14:20 UTC

Prevention Measures

  • Monitoring Enhancement: Enhanced monitoring of optical transceiver health metrics including temperature, signal strength, and error rates
  • Proactive Replacement: Implemented proactive replacement scheduling based on transceiver age and performance trends
  • Spare Inventory: Reviewed and restocked spare transceiver inventory for critical links
  • Predictive Analysis: Evaluating predictive failure analysis systems for optical components
  • Environmental Monitoring: Enhanced environmental monitoring for equipment rooms (temperature, humidity)
  • Supplier Diversity: Evaluating supplier diversity for critical optical components

Customer Communication

  • 07:30: Initial status update posted to status page
  • 09:00: Detailed incident report with timeline and projections published
  • 13:00: Update posted confirming hardware replacement arrival
  • 14:00: Service recovery notification sent to all affected customers
  • 14:20: Final resolution notice published

Incident resolved. All Netherlands traffic flows fully restored, network operating normally.

#optical #transceiver #netherlands #packet-loss #hardware #port-flapping